Case Study: Quicksilver Probe Focused fluid Extraction Increases Fluid Sample Purity by >60%

Novel probe design slashes fluid acquisition time and contamination levels in the Gulf of Mexico

Challenge: Collect fluid samples with less than 5% contamination from a highly deviated well drilled with oil-base mud in the Gulf of Mexico.

Solution: Acquire reservoir fluids using Quicksilver Probe focused fluid extraction for unprecedented purity and in a fraction of the time needed for conventional sampling.

Result: Reduced drilling risk by modifying drilling plans to use oil-base mud instead of water-base mud in consideration of the ability to acquire ultralow-contamination fluid samples.

Samples contaminated with oil-base mud filtrate

An operator in the Gulf of Mexico needed fluid samples with a contamination level of less than 5% from a key exploration well. Higher levels of filtrate contamination would produce unresolvable uncertainties in the laboratory analysis of fluid viscosity that would severely impair decision making.

Not only was the highly deviated well a challenging environment for extracting formation fluid, but the large viscosity contrast between the oil-base mud filtrate and formation fluid resulted in a minimum 40% contamination level in conventionally obtained samples after 500 min of pumping more than 0.189 m3 [50 galUS] of fluid.

The fluid purity needed in a fraction of the time

Quicksilver Probe focused fluid extraction took only 330 min in the same formation to flow fluid with a contamination level of less than 3% for sampling. Rig time—and associated risk—were reduced by one-third, whereas sample purity increased more than 60%.

Sample benchmark set at near-zero contamination

The analytical results gave the operator the confidence to change long-term drilling plans from using water-base mud to oil-base mud, which reduced drilling risk. Because the reliable technique of Quicksilver Probe focused fluid extraction makes it possible to successfully collect ultralow-contamination samples from this environment, the operator has further lowered the sample contamination target from 5% to 2%, effectively setting a new benchmark for state-of-the-art formation fluid acquisition.


Download: Fluid Sample Purity Increased by >60% (0.26 MB PDF)

Related products and services

 
 

Faster Fluid Extraction =
Less Rig Time and Risk

PrevNextZoom1 of 1

The Sample Purity You Need,
in a Fraction of the Time

Quicksilver Probe
The concentric probe design employed by Quicksilver Probe focused extraction acquires virtually contamination-free reservoir fluid for downhole fluid analysis and sample collection. Visit Quicksilver Probe page