Tech Report: Accuracy-Verified Water Salinity Measurement and First Water Detection in Multiphase Flow | Schlumberger
Tech Report
Details

The Netherlands, USA, and Singapore

Verification facilities

  • DNV GL, The Netherlands
  • Colorado Engineering Experiment Stations, Inc. (CEESI), USA
  • Schlumberger Singapore Well Testing Center (SWTC)
Background

The AquaWatcher Surface water analysis sensor was tested for robustness and the accuracy and repeatability of its water conductivity measurement (NaCl-equivalent salinity determination) and water volume fraction (WVF) detection at three wet gas and multiphase flow facilities.

The more than 300 flow loop test points acquired in a wide variety of flow regimes confirm excellent metrological performance and repeatability over a wide range of gas volume fractions (GVFs) up to 99.95% and within the operating range of the water/liquid ratio (WLR).

Products Used

Tech Report: Accuracy-Verified Water Salinity Measurement and First Water Detection in Multiphase Flow

Rigorous testing of the AquaWatcher Surface water salinity sensor in various flow regimes proves repeatable, highly accurate metrological performance

overflow image
Even in challenging high-GVF wet gas flows, the AquaWatcher Surface sensor performed flawlessly, delivering WVF detection at levels less than 100 ppm.