Part of our portfolio of SSS surface safety system actuators is the Model RV reduced-volume hydraulic actuator, which reduces the overall cost of the operating system. This actuator operates valves ranging from 2 to 4 in and valve working pressures to 5,000 psi [345 bar]. It also utilizes a translating cylinder design, which makes maintenance of the single T-seal inherently simple. The inspection window provides visual indication of the gate valve position and allows a side-mount magnetic limit switch to be installed.
The Model RV actuator’s design incorporates our patented Quick-Disconnect bonnet, permitting installation or removal of the actuator without depressurizing the gate valve. Additional model options include the RV with a one-piece stem and mechanical opener, and the RV with a heat-sensitive lock-open device.
Service for 2.5-in piston
Standard, H2S, and CO2 Service | Maximum Control Pressure |
Mounted on 2-in valve | (0.540 × valve pressure) + 213 psi [14.6 bar] |
Mounted on 2 1/2-in valve | (0.684 × valve pressure) + 278 psi [19.1 bar] |
Mounted on 3-in valve | (0.821 × valve pressure) + 282 psi [19.4 bar] |
Service for 3-in piston
Standard, H2S, and CO2 Service | Maximum Control Pressure |
Mounted on 4-in valve | (0.880 × valve pressure) + 75 psi [5.1 bar] |